We offer a wide range of products

On these pages, we show a selection of the thousands of products we can offer.
Feel free to contact us, and together, we will find exactly what you need for your construction.

FILTER

Ex ES 98 DL-11 -40°C

 

Ex position switch with safety function

  • Ex zone 1 and 21
  • Cold-resistant down to -40 °C
  • Metal enclosure
  • Design to EN 50041
  • Wiring compartment
  • Actuator: Long rocking lever DL
  • Actuating speed max. 2.5 m/s with a vertical actuating angle of 30°
  • Wear-resistant plastic roller
  • Lever angle adjustable in 10° steps
  • Actuator can be repositioned by 4 x 90°
  • Attention: Please state required international approvals with your order!

Technical data

Applied standards

EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN IEC 60079-7, EN 60079-31, EN ISO 13849-1, EN ISO 14119

Enclosure

aluminium die-cast, corrosion-resistant, powder-coated, anthracite grey, similar to RAL 7016

Cover

stainless steel 1.4401, powder-coated, signal yellow, similar to RAL 1003

Sealing

silicone

Switch type

type 1

Coding level

no coding

Degree of protection

IP66 (IEC/EN 60529)

B10d (10 % load)

2 million

TM

max. 20 years

Contact material

silver

Switching system

slow action, positive break NC contacts A

Switching elements

1 NC/1 NO contact, type Zb

Connection

screw connection terminals, use copper conductors only

Cable cross-section

min. 0.75 mm² (AWG 18), max. 1.5 mm² (AWG 16), incl. conductor ferrules

Cable entry

1 x M20 x 1.5 (incl. 1 cable gland)

Clamping range

7 … 13 mm

Rated impulse withstand voltage Uimp

4 kV

Rated insulation voltage Ui

250 V

Rated operating current Ie

max. 4.4 A T6 / max. 6.6 A T5

Rated operating voltage Ue

max. 250 VAC; 125 VDC

Utilisation category

AC-15; DC-13

Short-circuit protection

4 A / 6 A gG/gN fuse

Ambient temperature

T6: –40 °C … +70 °C (max. 4.4 A)
T5: –40 °C … +70 °C (max. 6.6 A)

Mechanical life

> 1 million operations

Operation cycles

max. 1800/h

Repeat accuracy of switching points

± 0.1 mm

Impact energy

max. 7 J

Ex marking

L II 2G Ex db eb IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80°C/T95°C Db
IECEx Ex db eb IIC T6/T5 Gb,
Ex tb IIIC T80°C/T95°C Db

Approvals

DMT 01 ATEX E 178
IECEx BVS 07.0014

Weight

425 g

Downloads

Mounting and wiring instructions – Ex 98

German, English, French, Italian, Portuguese

Data sheet – Ex ES 98 DL-11 -40°C

English

.steute