We offer a wide range of products

On these pages, we show a selection of the thousands of products we can offer.
Feel free to contact us, and together, we will find exactly what you need for your construction.

FILTER

Ex 13 WR 1Ö/1S – 5m

Ex position switch with safety function

  • Ex zone 1 and 21
  • Thermoplastic enclosure
  • Double insulated X
  • Suitable for in-line mounting
  • With pre-wired cable
  • Actuator: Roller plunger with collar WR
  • Actuating speed max. 0.5 m/s with a vertical actuating angle of 25°
  • Metal roller
  • Watertight collar for protection against penetration of dirt
  • Attention: Please state required international approvals with your order!

Notes

  • Actuator can be repositioned by 90° on request

Technical data

Applied standards

EN 60947-5-1, EN IEC 60079-0, EN 60079-1, EN 60079-31, EN ISO 13849-1, EN ISO 14119

Enclosure

thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0

Switch type

type 1

Coding level

no coding

Degree of protection

IP65 (EN 60079-0 + IEC/EN 60529), IP67 (IEC/EN 60529)

B10d (10 % load)

2 million

TM

max. 20 years

Contact material

silver

Switching system

slow action, positive break NC contacts A

Switching elements

1 NC/1 NO contact, type Zb

Connection

pre-wired cable H05VV-F

Cable cross-section

4 x 0.75 mm² (incl. conductor ferrules)

Cable length

5 m

Rated impulse withstand voltage Uimp

4 kV

Rated insulation voltage Ui

250 V

Conventional thermal current Ithe

T6: 6 A, T5: 3 A

Rated operating current/voltage Ie/Ue

6 A/250 VAC; 0.25 A/230 VDC

Utilisation category

AC-15; DC-13

Short-circuit protection

6 A gG/gN fuse

Ambient temperature

T6: –20 °C … +65 °C,
T5: –20 °C … +75 °C, +90 °C with max. 3 A

Mechanical life

> 1 million operations

Operation cycles

max. 1800/h

Repeat accuracy of switching points

± 0.1 mm

Contact opening

max. 2 x 4 mm

Impact energy

max. 7 J

Ex marking

L II 2G Ex db IIC T6/T5 Gb,
L II 2D Ex tb IIIC T80 °C/T95 °C Db
IECEx Ex db IIC T6/T5 Gb,
Ex tb IIIC T80 °C/T95 °C Db

Approvals

PTB 03 ATEX 1068 X
IECEx PTB 06.0053X
f a d Ô

Weight

440 g

 

Downloads

Mounting and wiring instructions – Ex 13

German, English, French, Italian, Portuguese

Data sheet – Ex 13 WR 1Ö/1S – 5m

English