We offer a wide range of products

On these pages, we show a selection of the thousands of products we can offer.
Feel free to contact us, and together, we will find exactly what you need for your construction.

FILTER

GMI D5062S Isolators

I.S. SIL2 Vibration Transducer Interface

The Vibration Transducer Interface D5062S is a high integrity analog input interface suitable for applications requiring SIL 2 level in safety related systems for high risk industries. It provides a fully floating dc supply for energizing vibration transducers, accelerometers or 2-3 wires sensors located in Hazardous Area, and repeats the sensor input voltage in a totally isolated circuit located in Safe Area to drive vibration monitors or analyzers for rotating machinery control and supervision purposes.

FEATURES

  • SIL 2 / SC 3
  • Input from Zone 0/Div. 1
  • Installation in Zone 2/Div. 2
  • 0 to –20 V Input/Output Signal
  • Wide band signal transfer
  • Input and Output short circuit proof
  • In-field programmability by DIP Switch
  • High Accuracy
  • Three port isolation, Input/Output/Supply

Teknisk data

Supply

Voltage 24 Vdc nom (18 to 30 Vdc), reverse polarity protected.
Current Consumption 90 mA @ 24 Vdc with 20 mA transducer consumption and 2 mA output load, typical.
Power Dissipation 2.0 W @ 24 Vdc with 20 mA transducer consumption and 2 mA output load, typical.

Input

Type 0 V to -20 V (10 kΩ impedance at terminals 7-8 or 8-9).
3 wires sensor supply voltage more than -22 V @ 0 mA supply, more than -17 V @ 15 mA supply (current limited @ ≈ 23 mA).
2 wires sensor supply voltage more than -17 V with constant current supply.
2 wires sensor supply current selectable @ 4 mA, 6 mA or 10 mA via internal DIP–Switch.

Output

Type 0 to -20 V on 10 kΩ load, with 10 Ω output resistance.
Response time ≤ 10 µs (10 to 90 % step change).
Frequency response DC to 20 kHz within 1 dB maximum.

Performance

Ref. Conditions 24 V supply, 10 kΩ load, 23 ± 1 °C ambient temperature
Calibration accuracy ≤ ± 0.1 % FSR
Linearity accuracy ≤ ± 0.05 % FSR
Temp. influence ≤ ± 0.005 % on zero/span for a 1 °C change.

Isolation

Test Voltage I.S. In/Out 1.5 kV; I.S. In/Supply 1.5 kV; Out/Supply 500 V

Environmental conditions

Operating temperature temperature limits –40 to +70 °C
Storage temperature temperature limits –45 to +80 °C

Safety description

Equipment Associated apparatus and non-sparking electrical equipment
Safety parameters Uo = 27 V, Io = 90 mA, Po = 576 mW at terminals 7-8-9-10. Ui = 30 V, Ci = 0 nF, Li = 0 nH at terminals 7-8-9. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.

Mounting

Type DIN-Rail 35 mm, with or without Power Bus or on custom Term. Board.
Weight about 125 g.
Connection by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm² (13 AWG).
Dimensions Width 12.5 mm, Depth 123 mm, Height 120 mm.

Nedladdning

Datasheet Engelsk

Instructions manual, 5254S

Instruction manual, D5062S Series

 

G.M. International srl